UNI-T UT321 Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
14 15
Excellent Control, Multifunction Controllers
ALM lamp
C / A / M mode keys
SV bar display
PV bar display
SV setting keys
MV operation keys
MV bar display
Status indicator lamps:
Display loop-2 PV(PV 2),
deviaton status (,,), alarm status
(AL 1, 2, 3, 4), cascade operation (CAS),
remote operation (REM1, REM2),
manual operation (MAN1, MAN2), and
operation stop (STP)
Light loader interface:
Communication port for
parameter setting by personal
computer and custom
computation downloading
PV/SP Data display
PV Inputs
Indication accuracy
Auxiliary Analog Input
Control scan period
Control loops
Number of Setpoint (SP)
Control Algorithm
SUPER, Auto tuning
Custom Computation
Control Outputs (MV)
Auxiliary Analog Output (4 to 20mA)
Loop Power Supply
Digital Inputs
Digital Outputs
RS485 Communication Protocol
Front Protection
General Approvals
Power Supply, Consumption
Size, weight
Ambient T, Limits RH
UT750, US1000 Specification Table
UT750
5 digits / 5 digits with LCD display
2 universal inputs (TCs, RTDs, mV, V)
0.1% 1digit
1 point
50, 100, 200, 500ms
1 or 2(cascade, dual)
8
ON/OFF, 3 position, PID (Continuous, Time-proportional), Heating & Cooling, Position-proportional PID
SUPER, SUPER2, AT
Standard
Select from 2 sets of Relays, Voltage Pulses or 4 to 20mA
1 point, 2 points when MV is relay output
1 point of 15V ( Cannot use with auxiliary analog output )
2 or 7
3 or 7
MODBUS, PC-link, Ladder, Coordinated Operation
IP55
UL, CE, CSA
90 to 264 V AC, max. 20VA
96(W)*96(H)*100(D)mm, 1kg
0 to 50 : , 20 to 90%RH
US1000
5 digits / 5 digits with Bar Graphs
SUPER, AT
Option
2 points of 24V
MODBUS, PC-link
IP65
CE, CSA, FM-non incendive
90 to 264 V AC, max. 25VA
72(W)*144(H)*149(D)mm, 0.8kg
Model and Suffix Codes
Model
UT750
Type
Options
Digital indicating controller
Single-loop type
Position-proportional type
Dual-loop type
None
Communication functions, auxiliary analog(remote) input
Suffix Code Description
-0
-1
-5
0
1
Model
US1000
Type
Options
Process controller
Basic type
Enhanced type(with custom computation)
Position-proportional type(with custom computation)
RS485 communication
LPS:Loop power supply for transmitter.
The two contact points in the US1000-21 relay item are the relay output and feedback input.
Universal
1
2
2
Voltage
1
1
1
Current
1
2
1
Voltage
1
1
1
Relay
0
2
2
Input
2
7
7
Output
3
7
7
LPS
1
2
2
Suffix Codes Description Analog output ContactAnalog input
-00
-11
-21
/A10
DI1 to DI7
DI1 to DI7
DO1 to DO7
DO1 to DO7
Contact input/output available
Contact outputContact input
Custom Computation for Sophisticated Control
Custom computation allows simple operation sequences and signal computations specific to the application to be speci-
fied, which the standard controller mode cannot deal with.
Input/output-related computations can be customized using 65 types of computation modules including arithmetical four-
rule operations, logical operations, special calculations,etc.
Controllers Equip Custom Computation
Model UT750 Indicating Controller
Model US1000 Process Controller, except US1000-00
Model UP750 Program Controller
Block Diagram of Custom Computation
The custom computation is executed in INPUT Block and OUTPUT Block.
Max.number of custom computation modules:
UT750,UP750 50 modules for each Block
US1000 30 modules for each Block
Computation Modules
Addition / subtraction / multiplication / division, Processing absolute value
/ reciprocal, Selecting maximum / minimum / average, Keeping maximum
/ minimum value, Keeping value, Rate of change limiter, Switch, Limiter,
Constant, AND, OR, Exclusive OR, NOT, Latch, Comparison (
,
,
,
,
), Not equivalent, Within range, Sum, Timer, Ten-segment linearizer,
Curve linearizer, Ratio, First order lag filter, Selection of PV from two
inputs, Temperature and humidity calculation, Parameter setting.
Custom Display Function
Data displayed on front panel, can be configured by using Custom Dis-
play Configuration Function.
Applications
Temperature & Pressure Compensation for Gas Flow Boiler Conbustion Control
Example for UP750
SQRT
FIC
PID
Temp
Compe.
Flow rate signal
retransmission
Pressure
transmitter
Differential
transmitter
Flow nozzle
Pt100
4 to 20mA
AIN2
AIN3
AIN1
Pressure
Compe.
UT750
Fuel flow
controller
Air flow
controller
Cross limit control
Boiler master controller
Boiler master signal
Boiler pressure
Flow pressure
Fuel flow Air flow
Module
Module
Control 1
Module
Module
Program control
Current/Pulse output
Analog input Contact input
Contact output
Custom
computation
Custom
computation
Module
Module Module
Module
Control 2
Module
Module
INPUT BlockINPUT Block
OUTPUT BlockOUTPUT Block
Page view 7
1 2 3 4 5 6 7 8 9 10 11

Comments to this Manuals

No comments