µR10000 Inteligent Industrial Recorder
Light Loader Enabling Exceptionally Simple Setting
for
for
US1000
US1000
only
only
for
US1000
only
1:1
1: N
ML2
RS-485
1: N
Ethernet
Gateway function
RS-485 Up to 31 units
Via Ethernet Communication
Connector
Via RS-485 Communication
Terminals
ML2 recommended for RS-232C/RS-
485 communication
Via Dedicated Adapter
Can be used while attached to the
control panel.
LL100/LL1100 PC-based Parameters Setting Tool
Parameter setting functions
Parameters that determine controller functions can easily be
set: controller model type, controller mode (single-loop control,
cascade control, loop control with PV switching, etc.), universal
input/output functions, setup parameters, program parameters,
and others.
Program Pattern Setting Display(LL100)
Model Suffix code Description
LL100
LL200
LL100 PC-based parameters setting tool, except for UM330/350, UM331/351, US1000, UT100 Series
LL200 PC-based custom computation building tool (LL100 functions are included), for UT750, UP750
English version (for Windows 98/2000 (Professional)/XP (Home Edition/Professional) and NT4.0)
- E10
Model Suffix code Description
LL1100
LL1200
LL1100 PC-based parameters setting tool, for US1000
LL1200 PC-based custom computation building tool (LL1100 functions are included), for US1000
English version (for Windows 95/98/2000 (Professional)/XP (Home Edition/Professional) and NT4.0)
- E10
Model and Suffix Codes
Related Instruments
UT150L/350L Limit Controller
The UT150L and UT350L are an FM approved
limit controllers that can be configured either as
a high limit or a low limit controller by a user.
The limit controllers feature universal input, two
alarm outputs, retransmission output, a timer to
count the total time the setpoint is exceeded, and
a register to retain the maximum temperature
reached.
The RS485 communication interface is available
optionally.
The UD300 series manual setters have PV display, and transmit
4 to 20mA DC by manual operation. It can be used as a remote
setter for digital indicating controllers like GREEN series control-
lers.
The SP (target setpoint) will be output in 3 seconds after the
change.
The TC, RTD or Voltage input is possible as PV input.
When the PV display is not necessary, it can be disappeared.
The two alarm outputs and a PV retransmission output are provi-
ded as standard.
The front panel has a splash-proof and dust-proof design
UD310
UD320
UD350
Model and Suffix Codes
Specifications
2 Alarm outputs and PV retransmission output in 4 to 20 mA built in as standard
Description
UD310 Manual Setter: 4 to 20 mA DC output (48 48 100 mm)
UD320 Manual Setter: 4 to 20 mA DC output (48 96 100 mm)
UD350 Manual Setter: 4 to 20 mA DC output (96 96 100 mm)
Always 0
Always 0
Power Supply 24V DC / 24V AC
PV / SP display
Input type
Input accuracy
Sampling period for PV
Number of manual setpoint (SP)
Manual setting output
PV Retransmission output, can be scaled
Alarm output
Power supply
Safety and EMC standard
Construction (from protection)
Dimensions and weight
Thermocouple
RTD
Voltage(mV, V)
Thermocouple
RTD
Voltage(mV, V)
Number of outputs
Types
UD310
UD320
UD330
4-digit PV / 4-digit SP
Universal inputs
K, J, T, E, R, S, B, N, L, U, Platinel 2
Pt100, JPt100
0 to 100mV, 0 to 5V, 1 to 5V, 0 to 10V
2: 1digit
1: 1digit
0.3: 1digit
500ms
1
4 to 20mA DC
4 to 20mA DC
2 relay contact, COM terminal is common
22 types
100 to 240 VAC or 24VAC/DC(option)
CSA, CE and UL
IP65 (UD310), IP55(UD320/UD350)
48(W)48(H)100(depth from panel face)mm, approx. 200g
48(W)96(H)100(depth from panel face)mm, approx. 300g
96(W)96(H)100(depth from panel face)mm, approx. 400g
Model
UD310
UD320
UD350
Fixed code
Fixed code
Option
Suffix code
-0
0
/V24
UD310/UD320/UD350 Manual Setting
Custom computation functions
You can create custom computations by combining computation
modules.
Module connection display(LL200)
LL200/LL1200 PC-based Custom
Computation Bulilding Tool
Tuning function
Used to tune a controller's PID parameters. Displays measured
input value, target setpoint, and control output value as a trend
graph on a personal computer screen, allowing PID parameter
modification, AUTO/MAN switching, control output modification
in manual operation, etc.
Tuning display(LL100)
Multi-Monitoring Fanctions
Measured values (PV), setting values (SP), and control output
values (OUT) are displayed as trends (online display).
Colors can be applied to trends as desired.
Just connect an instrument: the software detects the model
automatically (up to 16 loops).
Dedicated adapter/RS-485 Communication/ Ethernet Commu-
nication.
Multi-monitor Display
Specification
Recording width:
Chart length:
Number of inputs
Input type:
Measurement interval
Recording method
Recording period
Display:
Display types
Alarm levels:
Alarm type:
Optional specification:
Dimension:
Weight:
100 mm
16 m
Pen model: 1-4 pens
Dot model: 6 dot model
±20 mV to ±50 V, 1-5 V range
TC (R, S, B, K, E, J, T, N, W, L, U, WRe)
RTD (Pt100, Jpt100)
DC current (with external shunt register)
Pen model: 125 ms/channel
Dot model: 1 s/6 dot or 2.5 s/6 dot
Pen model: Disposable fel + pen, plotter pen
Dot model: 6 color wire dot
Pen model: consecutive recording
Dot model: max. 6 channel/10 sec
VFD 101 ¥ 16 full dot matrix display
Multiple displays digital, bar, flag, DI/DO display
etc can be displayed. 15 display types can be
selected from approx. 80 display types.
Up to 4 levels for each channel
High and low limit, differential high and low limit,
high and low rate-of-change, delay high and low
Alarm output, RS422A/485 communication,
Ethernet communication, Computation function,
Expansion inputs, Remote input etc.
Approx. 144 (W) × 144 (H) × 220 (D) mm
2.1 to 2.5 kg
µR10000 has carried over µR series high reliabil-
ity and basic functions. The 101 × 16 full-dot
matrix display allows it to monitor various on-site
data.
High reliability and high quality
Fully contact-less technology
High degree of integration using custom IC
Light weight (2.5 kg for 6 dot-model)
Dust and splash proof front
•Variety of line-up
1 to 4 pen model, 6 dot model
•Variety of input types
Universal inputs
Many input sensors available (35 input types
such as Pt50, PR20-40 etc)
Superior ease-of-operation
VFD 101 ¥ 16 full dot matrix display
Versatile operation display
Easily navigable interactive setting
New chart cassette
White LED
Analog record of computed result
(with computation option:/M1)
Network function
Ethernet, RS422A/485 communication option
Page view 9
1 2 ... 5 6 7 8 9 10 11