UNI-T UT713 Specifications

Browse online or download Specifications for Multimeters UNI-T UT713. UNI-T UT713 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Model UT713
OPERATING MANUAL
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - OPERATING MANUAL

Model UT713OPERATING MANUAL

Page 2

Figure 3MeasurementequipmentModel UT713: OPERATING MANUAL9

Page 3

1. Press the pushbutton to turn the Calibrator on.2. Press INPUT to display INPUT if the Calibrator is at output mode which displays OUTPUT.3. Pr

Page 4 - Unpacking Inspection

Figure 4OutputequipmentModel UT713: OPERATING MANUAL11

Page 5 - Safety Information

Follow the below procedure to start the cold terminal temperature auto compensationfunctions:1. Press the pushbutton to turn the Calibrator on.2.

Page 6

Because the temperature transducer aluminum plate is put at the back of theCalibrator, try to open the tilt stand if possible when operating the Calib

Page 7 - Turning the Calibrator On

Explanation of International SymbolsThe following symbols are used on the calibrator or in this operating manual. Thetable below explains their meani

Page 8 - Figure 2

WarningMaintenanceMake sure the calibrator is off and the test leads are removed from the inputterminals and the circuit under test before opening the

Page 9

Figure 5Periodically wipe the case with a damp clothand detergent; do not use abrasives orsolvents.l When the symbol appears on the display, re

Page 10 - Figure 3

WarningTo avoid personal injury or damage to the calibrator, use only a 125mA 250Vfuse for F1.In Input mode, the calibrator and TC are reliably connec

Page 11 - Model UT713: OPERATING MANUAL

Figure 6Replace the fuses using the following procedure:1. Remove the test leads from the calibrator terminals and turn the calibrator off.2. Remo

Page 12 - Figure 4

TABLE OF CONTENTSTITLE PAGE3346678101214151919IntroductionUnpacking I

Page 13

SpecificationsSpecifications are based on a one year calibration cycle and apply for ambienttemperature from +18 to +28 unless stated otherwise.Temp

Page 14

-20~1750-4~3182-20~1750-4~3182600~18001112~3272RSB0.04% 3( 100 )0.04% 5.4( 212 )0.04% 2( 100 )0.04% 3.6( 212 )1 or 1Temperature RangesThermoc

Page 15

Thermocouple TypeJ, K, T, E, N, R, S, BStandardNIST-175ScalesITS-90ModemVRange-10.00~110.00mV-110.0~1100.0mVAccuracy0.04% 2 digitsDisplay Resolution10

Page 16 - Maintenance

Resolution: TC: 0.1 or 0.1 (J, K, T, E, N); 1 or 1 (R, S, B). DC mV: 10 V (110mV range); 0.1mV (1100mV range) Cold Junction Error:

Page 17

* END *This operating manual is subject to change without notice.Model UT713: OPERATING MANUAL23

Page 18

Copyright 2007 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Page 19

TABLE OF CONTENTSTITLE PAGE212122Thermocouple Standards and ScalesMil

Page 20 - Specifications

DescriptionOperating ManualTest LeadAlligator Clip9V Alkaline Battery (1604A or 6LF22)IntroductionThe UNI-T Model UT713 Thermocouple Calibrator is a p

Page 21

WarningSafety InformationThis Meter complies with the standard CE EN61326.To avoid possible electric shock or personal injury:llllBefore using the cal

Page 22

lllllllReplace the battery as soon as the battery indicator appears. With alow battery, the Meter might produce false readings that can lead toelect

Page 23

Figure 1Press so thatOUTPUT is onthe displayPress and toincrement ordecrement a digit.Press and to stepup/down from 0 to 9 .Hold down to scro

Page 24

Figure 2Show TC type orvoltage rangeelectedPress so thatINPUT is on thedisplayInputPress to turn theMeter on and offInput TerminalsDisplay theselected

Page 25

1. Press the pushbutton to turn the Calibrator on.2. Press OUTPUT to display OUTPUT if the Calibrator is at input mode which displays INPUT.3. Pr