Single-loop control
Cascade primary-loop control
Cascade secondary-loop control
Cascade control
Loop control for backup
Loop control with PV switching
Loop control with PV auto-selector
Loop control with PV-hold function
Dual-loop control
Temperature & humidity control
Cascade control with two universal inputs
Loop control with PV switching and two universal inputs
Loop control with PV auto-selector and two universal inputs
Custom computation control
14 types of build-in Controller Functions
PV auto-selector
SELECT
PID
Dual-loop control
PID
PV switching
PID
Temperature & humidity control
Cascade control
Loop control for backup
PID
PID
PID
PID
PID
PID
Relative
Humidity
Calculation
PV
Operation with load causes
PV hunting.
Time
SP
PV
Changing SP causes hunting.
PV
Time
Control using SP
with the set PID.
PV
Time
SUPER 2 function suppresses hunting.
PV
Time
Control using SP
with the set PID.
SUPER 2 function suppresses
hunting even if SP is changed.
SUPER Function suppresses overshooting
The field-proven
SUPER
function utilizes built-in operator experience and fuzzy theory to deliver fine control and suppress overshooting.
The new
SUPER 2
function utilizes built-in operator experience and modern control theory to deliver fine control and suppress hunting.
Startup Program operation
Time
TimeTime
Temperature
Temperature
Temperature
Disturbance
SUPER:off
SUPER:on SUPER:on SUPER:on
When SUPER 2 function is not used When SUPER 2 function is used
When SUPER 2 function is not used When SUPER 2 function is used
Effect 1: For operation of empty furnace with the set PID
Effect 2: For changing SP
MODBUS Communication
A protocol used for communicating
with a general-purpose personal computer
and PLC.
Protocol: MODBUS RTU
MODBUS ASCII
Baud Rate: 600bps to 38.4kbps
(up to 9,600bps in case of MODBUS.)
Personal computer, or PLC
RS232C/RS485 converter
GREEN SERIES controllers
Max. 1200 m; up to 31 slave controllers can be connected
PLC
CX communication
A CX1000/2000 lets you control external UT controllers with same ease as
CX’s embedded controls.
Connectable models :UT320, UT321, UT350, UT351, UT420, UT450, UT520,
UT550, UT750
Personal Computer Link
Communication
A protocol used for communicating with a gen-
eral-purpose personal computer, or UT link
module and serial communication module of
PLC (FA-M3 range-free controller).
FA-M3 and a recorder can be connected in the same line.
Personal computer, or PLC
RS232C/RS485 converter
GREEN SERIES controllers
Max. 1200 m; up to 31 slave controllers can be connected
PLC
Coordinated Operation
In coordinated operation, a UP program controller or
UT digital indicating controller is used as a master con-
troller and multiple UT digital indicating controllers as
slave controllers. The slave controllers are operated in
accordance with the actions of the master controller.
Ladder Communication
A protocol used for communicating with a PLC.
Communication with a computer link unit of the
MELSEC-A series (made by Mitsubishi Electric Corpo-
ration) is possible.
() FA-M3 is the PLC made by Yokogawa.
FA-M3
()
Max. 1200 m; up to 31 slave controllers can be connected
GREEN SERIES controllers
UP program controller or UT digital indicating controller
GREEN SERIES controllers
Max. 1200 m; up to 31 slave controllers can be connected
Powerful Control Functions
Various functions for freely creating input/output-related computations
Communication Functions
Max. external loops:
4(CX1000), 16(CX2000)
(Two-loop controllers count as two loops each.)
CX1000 or CX2000
RS485, MODBUS
SUPER 2 Function suppresses hunting