Model UT805OPERATING MANUAL
81.2.3.4.5.6.7.8.9.Model UT805: OPERATING MANUAL1 2 3 456789101112The Meter StructureA. Front Panel (see figure 1)VFD DisplayPrimary Functional Button
910.11.12.Model UT805: OPERATING MANUALCAL Button: Calibrate the accuracy of Voltage,Current and ResistanceSecondary Functional Buttons: Different sid
101.2.3.4.5.6.7.8.Model UT805: OPERATING MANUAL1 2 3 4 5678B. Rear Panel (see figure 2)HI Input Terminal: 4-wire configuration to measure resistanc
11Model UT805: OPERATING MANUALFunctional ButtonsThe pushbuttons on the front panel select the Meter functions and operations. Below table indicated
12Model UT805: OPERATING MANUALButtonAC Current MeasurementIt is used to measure AC Voltage or Current with DC deviation:It is a calibration button:Pr
13Model UT805: OPERATING MANUALMAX MINSTO andRCLHOLDButtonPress MAX MIN to select the maximum and minimum value.HOLD has two features:1. Data Holding2
14Model UT805: OPERATING MANUAL1 2 3 4 5 6 7 8 9 10 11121314151617181920STORCLAUTOHOLDAC+DC TrueRMS MAX MIN AVGSmSkHzmVAnFMK WHzDisplay Symbols (se
15Model UT805: OPERATING MANUALNumber Symbol MeaningIndicator for high voltageData hold is activeIndicator for AC voltage or currentIndicator for AC A
16Model UT805: OPERATING MANUALNumber Symbol Meaning1213kHznFµFmFmAAmVVkMThe unit of frequency of AC measurement: Kilohertz (shown in the secondary di
17Model UT805: OPERATING MANUALNumber Symbol Meaning14151617181920Relative mode is onThe continuity buzzer is on.Primary DisplayIndicates negative rea
18To measure DC voltage, connect the Meter as follows:1.2.Model UT805: OPERATING MANUALCOMRLDCVMeasurement OperationIf you have not done so, plug the
193.Model UT805: OPERATING MANUALNoteWhen the Meter is not zero in manual range mode,you could short circuit the test lead and press RELto zeroing to
20To measure AC voltage, connect the Meter as follows:1.2.Model UT805: OPERATING MANUALACVCOMRLB. AC Voltage Measurement (See figure 5) Warnin
213.4.Model UT805: OPERATING MANUALNoteWhen the input terminal is short circuit, it is allowedto have maximum 500 digits of reading which doesnot affe
22To measure current, connect the Meter as follows:1.2.Model UT805: OPERATING MANUALCOMRLDCICOMRLACIC. DC or AC Current Measurement (see figure 6)
233.4.5.6.7.Model UT805: OPERATING MANUALNoteIf the value of current to be measured is unknown,use the maximum measurement position, and reducethe ran
241.2.Model UT805: OPERATING MANUAL WarningTo avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge al
253.4.1.2.3.4.5.6.Model UT805: OPERATING MANUALRxRLL0HITo obtain more accurate readings, you could short-circuit the test lead and press REL to dis
26Model UT805: OPERATING MANUALNoteWhen measuring high resistance (>1M ), it is normalto take several seconds to obtain a stable reading.In order t
271.2.3.Model UT805: OPERATING MANUALCOME. Testing Diodes (See figure 9) WarningTo avoid possible damage to the Meter and to thedevice under te
TABLE OF CONTENTSTITLE PAGE3455788101114181820222427293133353
284.Model UT805: OPERATING MANUALon the component’s anode and place the black testlead on the component’s cathode.The measured value shows on the prim
29To test for continuity, connect the Meter as below:1.2.3.Model UT805: OPERATING MANUALCOMRxF. Testing for Continuity (See figure 10) WarningT
30Model UT805: OPERATING MANUALNoteOpen circuit voltage around 1.2V.The primary display shows OL indicating the testedcircuit is open.When continuity
31To measure capacitance, connect the Meter as follows:1.2.3.Model UT805: OPERATING MANUALCOMG. Capacitance Measurement (See figure 11) Warning
324.Model UT805: OPERATING MANUALNoteIf the tested capacitance has polarity, connect thered test lead to the capacitor’s positive and the blacktest le
331.2.3.Model UT805: OPERATING MANUALCOMHzHzH. Frequency Measurement (see figure 12) WarningTo avoid harms to you, please do not attempt to inp
34Model UT805: OPERATING MANUALNoteWhen making frequency measurement, it must complywith the following scope (a) requirement:When 10Hz ~ 1Mz : 150mV
35Model UT805: OPERATING MANUALSelecting a Measurement Range ( , AUTO and Button)The Meter is default at DC Voltage 2V auto rangingmeasurement mode
36Model UT805: OPERATING MANUALThe Use of Relative Value ModeRelative Mode applies to all functions except continuity,diode and frequency measurements
37Model UT805: OPERATING MANUALMAX MIN ModeMAX MIN mode applies only to DCV, ACV, ACV andACI with DC deviation, and resistance. Press MAXMIN when the
2TITLE PAGE42434445464647484949505151525252535454555757585858
38Model UT805: OPERATING MANUALThe Use of STO and RCL ButtonSTO ButtonPress STO to step through 7 different storage speedincluding r=0, r=1, r=2, r=3,
39Model UT805: OPERATING MANUALOperation of Hold ModeThe Hold mode allows you to take a measurement andhold that measurement on the display. This fea
40Model UT805: OPERATING MANUALIcon Display: Equipped with functions and electrical unit symbol icon display.Polarity Display: AutoOverloadin
41Model UT805: OPERATING MANUALAccuracy SpecificationsAccuracy: (a% reading + b digits), guarantee for 1 year. Operating temperature: 230C 50C.Rel
42Model UT805: OPERATING MANUALB. AC Voltage (True RMS)Remarks:Overload Protection: 1000V DC or 750V ACInput Impedance:10MAC+DC Tolerance Limit: Same
43Model UT805: OPERATING MANUALRange Measurement Scope Resolution AccuracyC. DC CurrentRemarks:Overload Protection: At mA Range: Fuse 315mA, 250V,
44Model UT805: OPERATING MANUALD. AC Current (Frequency range: 40Hz~5kHz)Remarks:Overload Protection:At mA Range:Fuse 315mA, 250V, fast type, 5x20mm
45Model UT805: OPERATING MANUALE. ResistanceRemarks:Overload Protection : 1000V DC or 750V ACOpen Circuit Voltage:Around 2VllRange Measurement Scope
46Model UT805: OPERATING MANUALF. Diode TestRange Measurement Scope Resolution Overload Protection Remarks0.00~6.00V 10mV 250VpOpen circuit voltage ap
47Model UT805: OPERATING MANUALH. CapacitanceRemarks:Overload Protection: 250VplRange Measurement Scope Resolution Accuracy6nF60nF600nF6 F60 F600 F6m
3Model UT805: OPERATING MANUALOverviewThis Operating Manual covers information on safetyand cautions. Please read the relevant informationcarefully an
48Model UT805: OPERATING MANUALRange Measurement Scope Resolution AccuracyI. FrequencyRemarks:llOverload Protection: 250VpInput scope (a): (DC electr
49Model UT805: OPERATING MANUALA. DC Voltage (Calibrate both positive and negative polarity)CALIBRATION PROCEDURElllThe calibration must be done i
50Model UT805: OPERATING MANUALB. AC Voltage(750V range: frequency 1kHz, all other ranges: frequency 20kHz)200mV:2V :20V :200V :Input 1
51Model UT805: OPERATING MANUALC. DC Current (Calibrate both positive and negative polarity)2mA :200mA :10A :Press REL to display “0”, i
52Model UT805: OPERATING MANUALE. Resistance F. AC Voltage with DC deviation (AC+DC)1. Press ACV button2. Press AC+DC button3. Follow the above “B. AC
53Model UT805: OPERATING MANUALSUMMARY OF ERROR CODESIf the Meter is failed to operate properly, an error code is displayed in the primary display. E
54Model UT805: OPERATING MANUALMaintenanceThis section provides basic maintenance informationincluding general service and fuse replacementinstruction
551.2.Model UT805: OPERATING MANUALB. Replacing the Fuses (see figure 13) WarningTo avoid electrical shock or arc blast, or personalinjury or d
563.Model UT805: OPERATING MANUALthe fuse from its bracket. Then install thereplacement fuse.Install ONLY replacement fuses with the identicaltype an
57Model UT805: OPERATING MANUALRS232C and USB Serial PortSystem Requirements for Installing the UT805Interface ProgramlllllllAn IBM PC or equivalent c
4Item Description QtyModel UT805: OPERATING MANUALUnpacking InspectionCarefully remove the Meter from its shipping container and check the following i
58Model UT805: OPERATING MANUALRS232C Serial PortA. Connecting between the Meter and computer (see figure 14)B. RS232C Port CableD-sub9 Pin MaleCom
59Model UT805: OPERATING MANUALSerial port output 25 bits. Each bit is an alphabet, below table explains the meaning of each alphabet:Number12345$Sta
60Model UT805: OPERATING MANUALThe Meter adopts a single large alphabet command,each command is sent out twice as below table:When the Meter receives
61Model UT805: OPERATING MANUALUSB Serial PortA. Connecting between the Meter and computer (see figure 15)B. Setting of USB Serial PortsInstall th
62Model UT805: OPERATING MANUALThis operating manual is subject to change without notice. Copyright 2005 Uni-Trend International Limited.All rights
5Model UT805: OPERATING MANUALSafety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. I 10
6Model UT805: OPERATING MANUALEnsure the Meter is at right measurement positionrange. Disconnect the connection between the testlead and the circuit
7Model UT805: OPERATING MANUALInternational Electrical SymbolsAC or DCGroundingDouble InsulatedWarning. Refer to the Operating ManualHigh VoltageCont